EasyManua.ls Logo

Siemens SINUMERIK 840Di sl - 4.2 General functions and displays

Siemens SINUMERIK 840Di sl
274 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
3 Setting up functions 12/2008
3.2 Configuring measurements and measurement series
© Siemens AG 2008 All Rights Reserved
3-94 ePS Network Services, Function Manual (FH) - Release 12/2008
3.2.2 Equability test
Parameter description
Parameters for conducting an equability test:
Field Content Type
Name Name of the measurement series
(measurements do not have a name).
INPUT
Channel Selection of the required channel. The
channel defines the possible machine axes in
the "Axis" selection list.
SELECTION
Axis Selection of the possible machine axes that
can be programmed in the selected channel.
SELECTION
Start point The axis position at which the first partial
movement of the measurement begins.
INPUT
End point The axis position at which the first partial
movement of the measurement ends.
INPUT
Feed Velocity at which the axis is moved. INPUT
Fig. 3-10: Equability test on the operator panel

Table of Contents