3 Setting up functions 12/2008
3.4 Fault services
© Siemens AG 2008 All Rights Reserved
3-126 ePS Network Services, Function Manual (FH) - Release 12/2008
3.4.11 Server trigger on "Measurement series reaches limit value"
Description of functions
Any actions can be initiated if at least one of them has exceeded the limit value in
one of the measurement series configured in the trigger.
The trigger is only initiated if a limit value is violated at the point of the axis test.
Subsequent modification of the limit values to below the violation limit does not
trigger any actions.
Fig. 3-29: Trigger on measurement series reaches limit value
Field Content Type
Name Designation for the trigger; can be
entered by the user. If the field
remains empty, or the designation is
deleted, ePS Network Services will
generate a designation from the
selected measurement ranges. A
consecutive number (n) can be added
to this.
DISPLAY
INPUT
(Max. 40
characters; any
character
permissible)
Initiate trigger… Select type of limit value
• If at least one critical limit has been
exceeded
• If at least one warning limit has
been exceeded (in which case the
critical limit may also have been
exceeded)
• If only the warning limit has been
exceeded and the critical limit has
not yet been reached
SELECTION
1 of 3
Measurement
series
1-n of n
Display and selection of the existing
measurement series for the trigger
DISPLAY
SELECTION