12/2008 2 Maschine information
2.3 Test series on the machine
© Siemens AG 2008 All Rights Reserved
ePS Network Services, Function Manual (FH) - Release 12/2008
2-61
2.3.7 Contour test
Description of functions
A dry run is possible to ensure measurements can safely be performed on the
machine. The machine operator has the option of executing a dry run with reduced
velocity before beginning the test run configured to a specific type. This allows the
operator to test for safety path motions (contour monitoring) of the machine axes to
avoid collisions, etc.
Fig. 2-32: Selecting the contour test
Field Description Type
Contour test A contour test can be run to check that the
measurement part program is collision-free
before actual measurement.
The contour test can also be carried out with the
function "single block execution" active.
ACTION
Measurement Selection of the "Measurement type" tab. The
measurement can be performed once the notes
have been read and understood.
ACTION