Fig. 3-21: "Alarm group" trigger
Field Content Type
Alarm group name Name of the trigger; can be entered by
the user. If the field remains empty or
is deleted, the system generates a
name from the parameters of the
trigger. The name varies according to
the screen resolution.
If the name already exists, a
consecutive number is automatically
added in parentheses.
If the name is too long, the number
added can only be seen in a tooltip.
DISPLAY
INPUT
(Max. 40
characters; any
character
permissible)
Initiate the trigger at
the following alarms
Enter the alarms to be initiated:
List of individual alarms separated by
commas or alarm number areas
separated by "–".
DISPLAY
INPUT
(Max. 2000
characters; any
numerals
permissible)
, and – are
permissible
special
characters)
Exclude alarms Enters the alarms that must not result
in initiating: List of individual alarms
separated by commas or alarm
number areas separated by "–".
INPUT
Add / edit conditions
Opens the submenu for entering a
PLC condition.
ACTION