3 Setting up functions 12/2008
3.4 Fault services
© Siemens AG 2008 All Rights Reserved
3-116 ePS Network Services, Function Manual (FH) - Release 12/2008
Fig. 3-24: Timeout trigger
Field Content Type
Name Name of the trigger: If this is not
entered, the trigger is called Timeout
and assigned a consecutive number in
brackets.
DISPLAY
INPUT
(Max. 40 charac-
ters; any charac-
ter permissible)
Trigger start If the logic conditions are fulfilled for
start, monitoring starts for the specified
time
The logic operations are created as
described for the PLC variables.
ACTION
Trigger start name Displays the name specified in the
PLC variable configuration
DISPLAY
Trigger start
condition
Displays the condition specified in the
PLC variable configuration
DISPLAY
Trigger stop If the logic conditions are fulfilled for
stop, monitoring stops. Independently,
timeout times are also compared so
that the trigger can be triggered.
The logic operations are created as
described for the PLC variables.
ACTION
Trigger stop name Displays the name specified in the
PLC variable configuration
DISPLAY
Trigger stop
condition
Displays the condition specified in the
PLC variable configuration
DISPLAY
Monitoring time The monitoring time is the threshold DISPLAY