A Appendix
596
7UT613/63x Manual
C53000-G1176-C160-2
235.2125 Function $00 TRIP Delay Time
Out ($00 Time Out)
Flx OUT * * * LED BO
235.2126 Function $00 TRIP ($00 TRIP) Flx OUT * ON * LED BO
235.2128 Function $00 has invalid settings
($00 inval.set)
Flx OUT ON
OFF
**LEDBO
235.2701 >Function $00 block TRIP L12
(>$00 Blk Trip12)
Flx SP ON
OFF
on off * LED BI BO
235.2702 >Function $00 block TRIP L23
(>$00 Blk Trip23)
Flx SP ON
OFF
on off * LED BI BO
235.2703 >Function $00 block TRIP L31
(>$00 Blk Trip31)
Flx SP ON
OFF
on off * LED BI BO
235.2704 Function $00 Pick-up L12 ($00
Pick-up L12)
Flx OUT * ON
OFF
* LED BO
235.2705 Function $00 Pick-up L23 ($00
Pick-up L23)
Flx OUT * ON
OFF
* LED BO
235.2706 Function $00 Pick-up L31 ($00
Pick-up L31)
Flx OUT * ON
OFF
* LED BO
236.2127 BLOCK Flexible Function (BLK.
Flex.Fct.)
P.System Data 2 IntSP on
off
**LEDBO
251 Broken wire detected (Broken
wire)
Supervision OUT ON
OFF
**LEDBO
264 Failure: RTD-Box 1 (Fail: RTD-
Box 1)
Supervision OUT ON
OFF
* * LED BO 135 208 1 Yes
267 Failure: RTD-Box 2 (Fail: RTD-
Box 2)
Supervision OUT ON
OFF
* * LED BO 135 209 1 Yes
272 Set Point Operating Hours (SP.
Op Hours>)
SetPoint(Stat) OUT ON
OFF
* * LED BO 135 229 1 Yes
301 Power System fault
(Pow.Sys.Flt.)
P.System Data 2 OUT ON
OFF
ON * 135 231 2 Yes
302 Fault Event (Fault Event) P.System Data 2 OUT * ON * 135 232 2 Yes
311 Fault in configuration / setting
(FaultConfig/Set)
P.System Data 2 OUT ON
OFF
**LEDBO
312 Gen.err.: Inconsistency
group/connection (GenErrGroup-
Conn)
P.System Data 2 OUT ON * * LED BO
313 Gen.err.: Sev. earth-CTs with
equal typ (GenErrEarthCT)
P.System Data 2 OUT ON * * LED BO
314 Gen.err.: Number of sides / mea-
surements (GenErrSidesMeas)
P.System Data 2 OUT ON * * LED BO
320 Warn: Limit of Memory Data ex-
ceeded (Warn Mem. Data)
Device OUT ON
OFF
**LEDBO
321 Warn: Limit of Memory Parameter
exceeded (Warn Mem. Para.)
Device OUT ON
OFF
**LEDBO
321.2404 >BLOCK 3I0 time overcurrent 2
(>BLK 3I0 O/C 2)
3I0 O/C 2 SP * * * LED BI BO
321.2411 Time Overcurrent 3I0-2 is OFF
(O/C 3I0-2 OFF)
3I0 O/C 2 OUT ON
OFF
**LEDBO
321.2412 Time Overcurrent 3I0-2 is
BLOCKED (O/C 3I0-2 BLK)
3I0 O/C 2 OUT ON
OFF
ON
OFF
* LED BO
321.2413 Time Overcurrent 3I0-2 is
ACTIVE (O/C 3I0-2 ACT)
3I0 O/C 2 OUT ON
OFF
**LEDBO
321.2425 Time Overcurrent 3I0-2 picked up
(O/C 3I0-2 PU)
3I0 O/C 2 OUT * ON
OFF
* LED BO
321.2491 O/C 3I0-2: Not available for this
object (O/C 3I0-2 n/a)
3I0 O/C 2 OUT ON * * LED BO
No. Description Function
Type of Information
Log Buffers Configurable in Matrix IEC 60870-5-103
Event Log ON/OFF
Trip (Fault) Log On/Off
Ground Fault Log ON/OFF
Marked in Oscill. Record
LED
Binary Input
Function Key
Relay
Chatter Suppression
Type
Information Number
Data Unit
General Interrogation