A Appendix
598
7UT613/63x Manual
C53000-G1176-C160-2
323.2501 >BLOCK time overcurrent 3I0-3
InRush (>BLK 3I0O/C3Inr)
3I0 O/C 3 SP ON
OFF
ON
OFF
* LED BI BO
323.2502 >BLOCK 3I0>> time overcurrent
3 (>BLOCK 3I0-3>>)
3I0 O/C 3 SP * * * LED BI BO
323.2503 >BLOCK 3I0> time overcurrent 3
(>BLOCK 3I0-3>)
3I0 O/C 3 SP * * * LED BI BO
323.2504 >BLOCK 3I0p time overcurrent 3
(>BLOCK 3I0-3p)
3I0 O/C 3 SP * * * LED BI BO
323.2514 Time Overcurrent 3I0-3 3I0>>
BLOCKED (3I0-3>> BLOCKED)
3I0 O/C 3 OUT ON
OFF
ON
OFF
* LED BO
323.2515 Time Overcurrent 3I0-3 3I0>
BLOCKED (3I0-3> BLOCKED)
3I0 O/C 3 OUT ON
OFF
ON
OFF
* LED BO
323.2516 Time Overcurrent 3I0-3 3I0p
BLOCKED (3I0-3p BLOCKED)
3I0 O/C 3 OUT ON
OFF
ON
OFF
* LED BO
323.2521 Time Overcurrent 3I0-3 3I0>>
picked up (O/C 3I0-3>> PU)
3I0 O/C 3 OUT * ON
OFF
* LED BO
323.2522 Time Overcurrent 3I0-3 3I0>
picked up (O/C 3I0-3> PU)
3I0 O/C 3 OUT * ON
OFF
* LED BO
323.2523 Time Overcurrent 3I0-3 3I0p
picked up (O/C 3I0-3p PU)
3I0 O/C 3 OUT * ON
OFF
* LED BO
323.2524 Time O/C 3I0-3 3I0> InRush
picked up (3I0-3>InRush PU)
3I0 O/C 3 OUT * ON
OFF
* LED BO
323.2525 Time O/C 3I0-3 3I0p InRush
picked up (3I0-3p InRushPU)
3I0 O/C 3 OUT * ON
OFF
* LED BO
323.2529 Time Overcurrent 3I0-3 InRush
picked up (3I0-3 InRush PU)
3I0 O/C 3 OUT * ON
OFF
* LED BO
323.2541 Time Overcurrent 3I0-3 3I0>>
Time Out (3I0-3>>Time Out)
3I0 O/C 3 OUT * * * LED BO
323.2542 Time Overcurrent 3I0-3 3I0>
Time Out (3I0-3> Time Out)
3I0 O/C 3 OUT * * * LED BO
323.2543 Time Overcurrent 3I0-3 3I0p
Time Out (3I0-3p Time Out)
3I0 O/C 3 OUT * * * LED BO
323.2551 Time Overcurrent 3I0-3 3I0>>
TRIP (O/C 3I0-3>>TRIP)
3I0 O/C 3 OUT * ON * LED BO
323.2552 Time Overcurrent 3I0-3 3I0>
TRIP (O/C 3I0-3> TRIP)
3I0 O/C 3 OUT * ON * LED BO
323.2553 Time Overcurrent 3I0-3 3I0p
TRIP (O/C 3I0-3p TRIP)
3I0 O/C 3 OUT * ON * LED BO
324.2413 Dynamic settings O/C 3I0-3 are
ACTIVE (3I0-3 Dyn.s.ACT)
ColdLoadPickup OUT ON
OFF
ON
OFF
* LED BO
325.2404 >BLOCK Earth time overcurrent
2 (>BLK Earth O/C2)
Earth O/C 2 SP * * * LED BI BO
325.2411 Time Overcurrent Earth 2 is OFF
(O/C Earth2 OFF)
Earth O/C 2 OUT ON
OFF
**LEDBO
325.2412 Time Overcurrent Earth 2 is
BLOCKED (O/C Earth2 BLK)
Earth O/C 2 OUT ON
OFF
ON
OFF
* LED BO
325.2413 Time Overcurrent Earth 2 is
ACTIVE (O/C Earth2 ACT)
Earth O/C 2 OUT ON
OFF
**LEDBO
325.2425 Time Overcurrent Earth 2 picked
up (O/C Earth2 PU)
Earth O/C 2 OUT * ON
OFF
* LED BO
325.2492 O/C Earth2 err.:No auxiliary CT
assigned (O/C E2 ErrCT)
Earth O/C 2 OUT ON * * LED BO
325.2501 >BLOCK time overcurrent Earth
2 InRush (>BLK E O/C2 Inr)
Earth O/C 2 SP ON
OFF
ON
OFF
* LED BI BO
325.2502 >BLOCK IE>> time overcurrent 2
(>BLOCK IE-2>>)
Earth O/C 2 SP * * * LED BI BO
No. Description Function
Type of Information
Log Buffers Configurable in Matrix IEC 60870-5-103
Event Log ON/OFF
Trip (Fault) Log On/Off
Ground Fault Log ON/OFF
Marked in Oscill. Record
LED
Binary Input
Function Key
Relay
Chatter Suppression
Type
Information Number
Data Unit
General Interrogation