SITRANS FM100
page 40 A5E48762204-AA
Parameter table Info
Sublevel Description
Info
General Displays the measuring ranges of the device
Version Displays the hardware and software version
Manual Displays the QR code to download the instruction manual
10.10 Device default settings
The FM100 flowmeter is factory set and unloaded with the following configuration:
Display - Dual
Upper display - Flow
Lower display - Temperature
Out 1: IOLINK
Out 2: OFF
Important note for FM100 devices powered with software REV190320:
If output 1 should be operated as a current output, the conversion of the output
from IOLINK (factory setting) to current output must be made before the electrical
connection of the current loop. If this is not observed, the access to the menu
function is blocked and the device can no longer be configured.