7ML19985JF02 SITRANS LR250 (PROFIBUS PA) – INSTRUCTION MANUAL Page 17
mmmmm
Installation
• Joints: must be machined to (± 0.25 mm [± 0.010”]) and must have a welded
connecting sleeve on the outside
• Bypass vent is required at the upper end of the bypass
1)
• Algorithm (2.2.3.1.1.) must be set to Hybrid
Device orientation
Installation Instructions
Threaded Version
1. Before inserting the device into its mounting connection, check to ensure the
threads are matching, to avoid damaging them.
2. Simply screw the device into the process connection, and hand tighten, or use a
wrench. A torque of 40 N m (30 ft.lbs) is recommended
Flanged Version
See
Flanged Horn
on page 9 and
Flat Face Flange
on page 10 for dimensions.
1)
To equalize pressure and keep the liquid level in the bypass constant with the liquid
level in the vessel.
WARNING: For pressure applications, it will be necessary to use
PTFE tape or other appropriate thread sealing compound, and to
tighten the process connection beyond hand-tight.
Notes:
• The device can be rotated past 360° without damage. When mounting, orient the
front or back of the device towards the closest wall.
• Do not rotate the enclosure after programming and vessel calibration, otherwise
an error may occur, caused by a polarity shift of the transmit pulse.
align front or
back of
device with
vents
align front or back
of device with
stillpipe slots
Stillpipe Installation
stillpipe
slot
ypass Installation