EasyManua.ls Logo

Siemens SIWAREX WL260 Series - Siwarex Wl280 Rn-S Sa

Siemens SIWAREX WL260 Series
98 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
9.1.16 SIWAREX WL280 RN-S SA
Table 9-17 Technical data SIWAREX WL280 RN-S SA
Variable Value
Type series WL280
Designation RN-S SA
Construction type Ring torsion load cell
Possible applications Container weighers,
conveyor scales,
platform scales,
roller table scales
Rated load E
max
0.06; 0.13; 0.28; 0.5; 1; 2; 3.5; 5;
10; 13; 28; 60 t
Accuracy class according to OIML R60 C3
Max. scale interval n
LC
3000
Minimum scale interval V
min
for E
max
= 0.06; 0.13; 0.28 t
for E
max
= 0.5; 1; 2; 3.5; 5; 10; 13; 28; 60 t
E
max
/ 16000
E
max
/ 17500
Combined error F
comb
≤ ± 0.02% C
n
Min. initial loading E
min
0 kg
Maximum working load L
u
for E
max
= 0.06; 0.13; 0.28 t
for E
max
= 0.5; 1; 2; 3.5; 5; 10; 13; 28; 60 t
200% E
max
150% E
max
Break load L
d
for E
max
= 0.06; 0.13; 0.28 t
for E
max
= 0.5; 1; 2; 3.5; 5; 10; 13; 28; 60 t
500% E
max
300% E
max
Maximum lateral load L
lq
for E
max
= 0.06; 0.13; 0.28 t
for E
max
= 0.5; 1; 2; 3.5; 5; 10 t
for E
max
= 13; 28; 60 t
75% E
max
100% E
max
75% E
max
Rated measuring path h
n
For E
max
= 60; 130; 280 kg:
For E
max
= 0.5; 1; 2; 3.5; 5; 10 t:
For E
max
= 13; 28; 60 t:
0.07 mm
0.1 ± 0.02 mm
0.11 to 0.2 mm
Supply voltage U
SR
for E
max
= 0.06; 0.13; 0.28 t
for E
max
= 0.5; 1; 2; 3.5; 5; 10 t
for E
max
= 13; 28; 60 t
15 V
10 V
15 V
Rated characteristic value C
n
for E
max
= 0.06; 0.13; 0.28 t
for E
max
= 0.5; 1; 2; 3.5; 5; 10; 13; 28; 60 t
1 mV/V
2 mV/V
Tolerance of zero signal D
o
≤ ± 1.0% C
n
Technical data