SIWAREX WL200
Operating Instructions, 07/2016, A5E02199611B-03
7
Purpose of this documentation
These instructions contain all information required to commission and use the device. Read
the instructions carefully prior to installation and commissioning. In order to use the device
correctly, first review its principle of operation.
The instructions are aimed at persons mechanically installing the device, connecting it
electronically, configuring the parameters and commissioning it, as well as service and
maintenance engineers.
Technical support (Page 99)
The following versions of this documentation have been released to date. The changes apply
to the previous version:
Table 1- 1 History
10/2008 Initial release
04/2009 Addition to SP-S SA 30 t load cell.
Designation updated: WL200 instead of WL 200.
Corrections made mainly to the specifications.
Additions to explosion protection and ATEX approval
Addition to WL280 RN-S SA 10 t; 13 t; 28 t and 60 t load cells.
09/2010 Addition to WL280 RN-S SA 60 kg to 5 t load cells
Addition to WL270 K-S CA load cells
02/2013 WL270 K-
S CA load cells with additional versions (high temperature, double
bridge) and extended operating range up to 500 t. WL260 SP-S SB load
cells and WL260 SP-S SC load cells.
Expansion of the load cells WL270 K and WL280 RN for hazardous areas
Dimensions of WL250 ST-S SA changed.
Integration of load cell WL260 SP-S AE
03/2015 Integration of load cell WL230 SB-S CA. Description of nameplate und
ATEX label.
Addition to load cell WL290 DB-S CA