Scale parameters and functions
8.3 DR 3 Calibration parameters
SIWAREX WP251
64 Manual, 12/2015, A5E37203357A
Automatic zero tracking
(Page 69)
0: Only outside the
dosing cycle
1: Also inside the
BOOL 0 0 0 1 x 1032
Maximum tare load
(Page 70)
Range of subtractive,
semi-automatic taring
[in % of maximum
FLOAT 4 100 0 250 x 1034
Maximum negative zero
setting limit (power-on)
(Page 70)
Negative range of
semi-automatic zero
setting [in % of maxi-
FLOAT 4 0 0 100 x 1036
Maximum positive zero
setting limit (power-on)
(Page 70)
Positive range of
semi-automatic zero
setting [in % of maxi-
mum weighing range]
FLOAT 4 0 0 100 - 1038
Maximum negative zero
setting limit (semi-
automatically) (Page 70)
setting (initial zeroing)
[in % of maximum
FLOAT 4 1 0 100 x 1040
Maximum positive zero
setting limit (semi-
automatically) (Page 71)
Positive range of zero
setting (initial zeroing)
[in % of maximum
FLOAT 4 3 0 100 x 1042
Standstill 1 - range
(Page 72)
Standstill range 1,
specification in numer-
FLOAT 4 1 0 9,999,9
99
x 1044
Standstill 1 - time
Standstill time 1 (ms) TIME 4 1000 10 10,000 x 1046