05.2006 Parameterizing Steps
Siemens AG 6SE7087-2JD60
SIMOVERT MASTERDRIVES Operating Instructions 9-23
87654321
Setpoint source
MASTERDRIVES VCUSS1 (P368=4) with Simatic
- s4 -
P572.1
B (2112)
B2115 External fault
Src Neg. Spd
B2114 Raise MOP
B2110 PcD control
B2112 Negative Spd
P571.1
B (2111)
B2111 Positive Spd
B2109 Jog Bit1
P568.1
B (2108)
B2108 Jog Bit0
P565.1
B (2107)
B2107 Acknowledge
B2106 Setpoint Release
B2105 No RGen Stop
B2104 RGen Release
B2103 Inv. Release
B2102 OFF3 (QStop)
P555.1
B (2101)B2101 OFF2 (electr.)
B2215
Src Pos Spd
Src Jog Bit0
Src 1 Acknow
Src OFF2
B2200
Bit0
up to Bit15
K2002
P486.B
K
Src T setpoint
SComWord2
r709.2
P443.B
K (2002)
Main setpoint
K2001
SCom1Word1
r709.1
P707.1(32)
K
K0032
ZUW1
r552
Status word
from sheett
[200]
P707.2
K
KK0148
n/f(act)
from sheet
[350.7], [351.7]
[352.7], [400.7]
Transmit actual values
Receive setpoints
Bit15
Bit14
Baud rate
P701.1
PKW #
P702.1
PcD #
P703.1
PKW: 4
PZD: 2
Baud rate:
9.6 kB
PKW PKW PZD1 (Data word1) PZD2 (Data word 2)
PKW PKW PcD1 (Data word 1) PZD2 (Data word 2)
Control word
B2100 ON/OFF1
Bit0
Bit1
Bit7
Reserved for write operations of
parameter data
Reserved for read
operations of
parameter data
Sheet [100]
Sheet [110]
P700.1 = Bus address
P704.1 = Tlg failure time
B2113 Raise MOP
For T control:
• • • • •
• • • • •
to sheet [180]
control word 1
r550
/10 / 35
RS485P
/11 / 36
RS485N
PcD1 (Data word1)
Reserve
pos./neg. speed setp
Ramp-function gen. active
Energize main cont.
Undervoltage fault
Comp. Setp reached
PZD control
Set/actual deviation
Alarm effective
Switch-on ihibit
OFF3 effective
OFF2 effective
Fault effective
Operation
Ready
Ready for ON
15 0
1
ZUW1
P554.1
B (2100)
Src ON/OFF1
Receive
Transmit
-X101 / -X100
to sheet [316.1]
to sheet [320.1]
N
M
n959.85 = 4
<1> Only applicable for Compact/Chassis type unit