EasyManua.ls Logo

Siemens Vector Control - Page 320

Siemens Vector Control
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Parameterizing Steps 05.2006
6SE7087-2JD60 Siemens AG
9-28 Operating Instructions SIMOVERT MASTERDRIVES
87654321
Setpoint source
MASTERDRIVES VCOP1S and MOP (P368=8)
- s81 -
Terminal strip
Sheet [90]
P
I O
B2100
P554.1 (5)
B
ON/OFF 1 Src ON/OFF1
B2113
P573.1 (8)
B
Raise MOP
B2114
P574.1 (9)
B
Lower MOP
Src Raise MOP
Src Lower MOP
n959.91 = 4
/5
/4
/3
/2
/1
B0014
P653.1 (0)
B
B0012
P652.1 (104)
B
B0010
P651.1 (107)
B
M24
P24
-X101
B0104
B0107
operation
0=fault
*
)
*
)
1=operation
no fault
*
)
P590 (14)
B
Src BICO DSet
B2107
P565
B
1 Acknowledge
Src1 Acknowledge
B2112
P572
B
Negative Spd
Src Negative Spd
MOP MP Sheet [300]
Accel Time MOP
P431
P443.B (58)
KK
Src Main Setpoint
MOP(Outp.)
r424
P425
Conf MOP
KK058
MOP(Outp.)
P486.B (58)
KK
Src T Setpoint
(for T control )
Decel Time MOP
P432
MOP (max)
P421
P422
MOP (min.)
0xx0 = ... without storing after OFF
0xx1 = ... storing after OFF
Raise MOP
Lower MOP
to sheet [316.1]
to sheet [320.1]
N
M
to sheet [180]
from sheet [200]
Not valid for Compact PLUS!