EasyManua.ls Logo

Siemens XC1005-A User Manual

Siemens XC1005-A
102 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
A6V10257473_e_en_--
Building Technologies
2015-03-04 Control Products and System
XC10
Extinguishing control unit
XC1001-A / XC1005-A /
XC1003-A
Installation
Commissioning
Maintenance

Table of Contents

Other manuals for Siemens XC1005-A

Question and Answer IconNeed help?

Do you have a question about the Siemens XC1005-A and is the answer not in the manual?

Siemens XC1005-A Specifications

General IconGeneral
ManufacturerSiemens
ModelXC1005-A
Supply voltage24 V DC
Digital inputs8
Protection ClassIP20
Communication interfaceRS485
Operating Temperature Range-20°C to +60°C
Relative Humidity5% to 95% (non-condensing)
Housing MaterialPlastic
MountingDIN rail

Summary

Safety instructions

Danger levels

Explains pictograms indicating danger severity and consequences.

Safety instructions

Outlines general safety rules for installation and maintenance.

Standards and directives complied with

Lists standards and directives the product adheres to.

Overview

Features

Installation

Connections

Mains Connection

Explains the procedure for connecting the main power supply.

Battery Connections

Details how to connect the 12V batteries for power supply.

Battery Capacity Calculation

Provides formula and examples for calculating battery capacity.

Fire Detectors and Manual Release Wiring

Covers wiring for detectors and manual release controls.

Wiring for Explosion Hazard Areas

Specifies wiring requirements for hazardous environments.

Monitored Inputs

Explains the connection and function of monitored inputs.

Control Inputs

Describes the connection and use of control inputs.

Monitored Control Outputs

Details the technical data for monitored control outputs.

Programmable Outputs

Explains the use of programmable driver and relay outputs.

24V Power Supply Output

Details the 24V power supply output and protection.

Repeater Terminal and Display Connection

Covers connection of repeater terminals and displays.

Multi-sector installation

Operating access levels

Programming

Before starting

Explains programming options and their effects on outputs.

Presettings

Details country-specific and factory presetting options.

Time duration settings

Configures pre-discharged warning and activation times.

Output and Input Configuration

Covers programming for sounders, remote transmission, monitored outputs, and inputs.

System State Configuration

Configures reset, operation modes, faults, and control inputs.

Zone and Access Level Configuration

Manages detection zones, access levels, multi-sector, and repeaters.

Specific Functions Configuration

Configures fire dampers, warning times, and discharge operations.

Commissioning

Powering

Step-by-step guide for powering up the control unit.

Maintenance

Test functions

Advanced functions

Special functions

Connection to Sinteso / Cerberus PRO panels

Related product manuals