Do you have a question about the Siemens XC10 Series and is the answer not in the manual?
Supply voltage | 24 V DC |
---|---|
Digital inputs | 8 |
Mounting | DIN rail |
Protection Class | IP20 |
Operating Temperature | -20°C to +60°C |
Storage Temperature | -40°C to +70°C |
Describes the installation, commissioning, and maintenance of the XC10xx-A equipment.
Defines the document's validity for market package MP2.1 and country-specific components.
Lists the intended personnel groups (managers, installers, technicians) for the document.
Explains hazard pictograms, electrical safety, and general installation precautions.
Lists safety standards and directives with which the product complies.
Details compliance with EN12094-1 and EN54-2 standards and optional functions.
Describes XC1001-A, XC1005-A (wall mounting), and XC1003-A (19" rack cabinet).
Identifies key components like FCP1004-E power supply and XCM1002 mainboard.
Explains the indicators, keys, and 4-digit display of the XC10xx-A user interface.
Details technical specifications for power supply, detection lines, inputs, outputs, and mechanical data.
Provides steps for mounting the XC1001-A and XC1005-A on a fixed support.
Details fitting the XC1003-A into a 19" housing cabinet with IP protection.
Explains how to connect the unit to the mains power supply and batteries.
Details connecting fire detectors, alarm contacts, and manual triggering devices.
Covers connections for monitored inputs, control inputs, and monitored control outputs.
Explains connections for programmable driver outputs, relay outputs, and 24V power supply output.
Describes how multi-sector extinguishing systems protect multiple flooding zones.
Details the functions of the XCA1031 common module in multi-sector applications.
Explains the role of the XCA1030 module within each XC1003-A panel.
Shows how to assemble and connect XCA1030 and XCA1031 modules for multi-sector systems.
Describes FCA1007 key switch and FDCI222/FDCIO222 for system integration.
Explains how to connect a remote transmitter for monitoring and control.
Defines the functions accessible at different operating access levels (1, 2, 3A, 3B).
Illustrates extinguishing processes initiated by automatic, manual, and mechanical releases.
Covers entering programming mode and selecting country-specific presettings.
Configures pre-discharged warning time, activation durations, sounders, and remote transmission.
Details programming for monitored outputs, relays, driver outputs, inputs, reset, and operation modes.
Covers fault display, detection zone settings, access levels, multi-sector, and detector types.
Steps for powering the unit, connecting batteries, and selecting presettings.
Details the procedure for calibrating monitored control outputs 4 and 5.
Guides through performing a system test and validating the commissioning process.
Outlines weekly, annual, 2-year, and 4-year maintenance tasks for the equipment.
Explains how to interpret fault indicators and their meanings for troubleshooting.
Describes lamp test, sounder test, and warning panels test procedures.
Details RT-alarm test, RT-fault test, and the overall system test procedure.
Explains how to perform individual output tests and zone tests for detectors.
Guides on testing the DM1103-L manual release buttons.
Covers checking programming modifications and displaying the fire alarm count.
Explains functions for controlling sounders during pre-warning and performing anticipated resets.
Details PC connection requirements for programming, event memory, and alarm counter.
Lists complete products, accessories, and spare parts with their part numbers and descriptions.