EasyManua.ls Logo

Sime BRAVA ONE BF - Technical Specifications

Sime BRAVA ONE BF
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
54
EN
5.5 Technical features
DESCRIPTION
Brava One 25 BF Brava One 30 BF
CERTIFICATIONS
Country of intended installation DZ - TN
Fuel G20 - G30/G31
PIN number 1312CP5935
Category II2H3+
Type
B22P - B32P - B52P
C12 - C12X - C32 - C32X - C42 - C42X - C52 - C52X
C62 - C62X - C82 - C82X - C92
Class NO
x
3 (< 150 mg/kWh)
HEATING PERFORMANCE
HEAT INPUT
Nominal kW 25,5 30,0
Minimum kW 9,2 10,8
HEAT OUTPUT
Nominal (80-60°C) kW 23,7 28,1
Minimum (80-60°C) kW 7,8 9,2
EFFICIENCY
Max useful efficiency (80-60°C) % 93,0 93,7
Min useful efficiency (80-60°C) % 84,8 85,2
Useful efficiency at 30% of load (50-30°C) % 90,5 91,1
Thermal efficiency (EEC 92/42)
Losses after shutdown at 50°C W 71 75
DOMESTIC HOT WATER PERFORMANCE
Nominal heat input kW 25,5 30,0
Minimum heat input kW 9,2 10,8
D.H.W. flow rate ∆T 30°C l/min 11,3 13,0
Continuous D.H.W. flow rate (∆T 25°C / ∆T 35°C) l/min 13,6 / 9,7 16,1 / 11,5
Minimum D.H.W. flow rate l/min 2,2 2,2
Max / Min Pressure
bar 7 / 0,4 7 / 0,4
kPa 700 / 40 700 / 40
ELECTRICAL SPECIFICATIONS
Power supply voltage V 230
Frequency Hz 50
Absorbed electrical power W 112 113
Electrical protection degree IP X5D
COMBUSTION DATA
Smoke temperature at Max/Min flow (80-60°C) °C 142,5 / 96,4 151,9 / 100,8
Smoke flow Max/Min g/s 17 / 16 19 /19
CO
2
at Max/Min (G20) flow rate with separate chimneys % 6,7 / 2,1 7,1 / 2,3
CO
2
at Max/Min (G31) flow rate with separate chimneys % 7,7 /2,6 7,8 /2,7
NOZZLES  GAS
Number of nozzles No. 11 13
Nozzle diameter (G20) mm 1,30 1,30
Nozzle diameter (G30/G31) mm 0,80 0,78
Gas consumption at Max/Min flow rate (G20) m
3
/h 2,70 / 0,97 3,17 / 1,14
Gas consumption at Max/Min flow rate (G30) kg/h 2,01 / 0,72 2,36 / 0,85
Gas consumption at Max/Min flow rate (G31) kg/h 1,98 / 0,71 2,33 / 0,84
Gas supply pressure (G20/G30/G31)
mbar 20 / 28-30 / 37
kPa 2 / 2,8-3 / 3,7
TEMPERATURE  PRESSURE
Max operating temperature °C 85 85
Heating adjustment range °C 20 ÷ 80 20 ÷ 80
Domestic hot water adjustment range °C 10 ÷ 60 10 ÷ 60
Max operating pressure
bar 3
kPa 300
Water content in boiler l 3,05 3,65
Lower Heat Output (Hi)
G20 Hi.
9.45 kW/m
3
(15°C, 1013 mbar) -
G30 Hi.
12.68 kW/kg (15°C, 1013 mbar) -
G31 Hi.
12.87 kW/kg (15°C, 1013 mbar)

Table of Contents