6.13.2 EMPTYING operations
Domestic hot water circuit:
close the domestic hot water circuit isolation valve
(prearranged in installation)
open one or more than one hot water valve to fill and bleed the
domestic hot water circuit.
Boiler:
loosen the automatic bleed valve (3)
close the heating circuit isolation valves (prearranged in
installation)
check that the filling valve (4) is closed
connect a rubber hose to the boiler drain valve (7) and open it
when it has fully emptied, close the drain valve (7)
close the automatic bleed valve (3).
4
3 7
Fig. 39