Simrad GC80/GC85 Expanded Gyro Compass
50 20221529 / C
5 Press the DISP button again to select sub-category 1.2.F,
and use the arrow buttons to increase or decrease the
parameter value until the value corresponds with the
parameter for the new sensitive element. Confirm the entry
by pressing the ACK/ENT button.
6 Repeat step 5 for sub-category 1.3.S, 1.4.u, 1.5.L and
1.6.t.
7 Press the SET button again to return to main category A1,
and then press the DISP button to go to A2 main category.
8 Press the
SET button, and enter values for 2.1.o and 2.3.h
as described above.
While still in A2 main category, enter values for 2.5.y (Year),
2.6.N (Month and Day), 2.7.t (Hour and Minute) and 2.8.d (total
days of operation. This value should be reset after installation).
Note! All time parameters should be in CET (Central European Time)
or local time.
9 Press the SET button again to return to main category A2,
and then press the DISP button until main category A7 is
displayed.
10 Press the
SET button, and enter the value for 7.3.u as
described above.
11 Exit the sub-category by pressing the
SET button, and then
exit the Extension main category by pressing and holding
the SET and ACK/ENT buttons simultaneously for at least
3 seconds.
For more information about the Extension menu, see
ADVANCED SETTINGS, page 55 onwards.