DIP SWITCH SETTINGS
20221529 / C 91
SCC board
BT1
J10
J9
4
4
2
2
4
J8
3
1
3
3
1
J4
SW2
6
2
J7
2
2
J6
J5
SW1
ON
ON
ON
SW3
ON
SW4
5
1
1
1
8
1
1
1
8
1
8
6
U1
J3
U52
J1
21
J2
DIP switch settings on SCC board
SWITCH DEFAULT FUNCTION DESCRIPTION
S1-1 OFF Control unit type OFF = Expanded, ON =Compact
S1-2 - Master compass type OFF = Standard, ON =High Speed
S1-3 - 2 gyros used OFF = Single, ON =Dual
S1-4 - Active gyro system OFF = System No.1, ON =System No.2
SW1-5 OFF
SW1-6 OFF
= No external sensor
SW1-5 OFF
S1-5 OFF
SW1-6 ON
= Magnetic system
connected (back-up)
SW1-5 ON
SW1-6 OFF
= External sensor connected
SW1-5 ON
S1-6 OFF
External sensor
connection
SW1-6 ON
= External system connected
(back-up)
S1-7 OFF Serial signal format OFF = IEC61162-2 (NMEA0183, ref. page 4),
ON = Tokimec
S1-8 OFF Alarm output setup OFF = All alarms,
ON = Only power failures