The Alerts dialog
The Alerts dialog is activated from the Alert settings or from the main menu.
The Alerts dialog includes a list of active alerts together with a historic listing of the last alert
state changes. Entries are added to the history whenever an alert is raised, acknowledged,
rectified or cleared.
All alerts in the Alerts dialog include a time stamp.
Alphabetic alert list
Alert type abbreviations:
C: Caution
A: Alarm
Alert text Description Type
BAM heartbeat lost
No HBT message is received. Only relevant if one or
more NMEA 0183 ports are configured as BAM interface.
C
Depth missing No depth data from selected sensor C
Low voltage Supply voltage <10 V (12V-15%) C
No time source
No time data from NMEA 2000 or NMEA 0183 position
sensor. Only relevant if the time setting is Auto.
C
Shallow water Depth shallower then set limit A
The alert system | S3009 Echo Sounder User Manual