© Jan 2022 6-38 0607SE Maintenance Manual
REPAIR
Problem Cause Solution
The hydraulic valve is malfunctioning.
Tilting warning
The level switch is abnormal
The level switch air bubble is not in the middle
position.
The level switch is not connected properly or firmly.
The ground controller is malfunctioning.
No overload warning
The load has not been
calibrated or the height is
incorrect
The sensor has not been calibrated.
The wiring of the load sensor is incorrect.
The sensor is not in good condition.
The machine moves
and then stops
intermittently
The battery level is low/the
calibration is incorrect
Re-calibrate the parameters.
The battery is out of power. The electricity meter
only can be referred.
After setting, the
parameters could not
be saved successfully
after several trials.
The storage is abnormal
The parameters cross the line.
The lower platform controller is malfunctioning.