EasyManuals Logo

SKF KFA1 series User Manual

SKF KFA1 series
60 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #38 background imageLoading...
Page #38 background image
7. Electronic control unit Page 38
EN
Continuation of Table 20. Explanation of display contents of the three-digit LED display (KFAS)
Display
Explanation of
characters
Explanation
Value range
Factory setting
Fault Cycle Switch
"Cycle switch" fault message
No signal from cycle switch during contact time.
-
-
Fault Low Level
"Fill level" fault message
The level in the reservoir has fallen below the minimum fill level.
-
-
Operation
hour meter
Operating hour meter
The following figures indicate the operating hours of the control unit.
Two display values appear:
Display 1: The first three digits of the value.
Display 2: The last two digits and one decimal place.
0.1 99999.9 hours
not deletable
0 hours
Fault hour meter
Fault hour meter
The following figures indicate the fault hours of the control unit.
Two display values appear:
Display 1: The first three digits of the value.
Display 2: The last two digits and one decimal place.
0.1 99999.9 hours
not deletable
0 hours
block
Block mode
No signal from cycle switch. Unlike in normal mode, the control unit is
still in the monitoring sequence. A fault message is issued if the fault
remains for three contact times.
-
-