7. Electronic control unit Page 44
EN
Continuation of Table 24. Change mode of operation (KFAS)
Step
Button
Action
Display
3
Press briefly.
The display switches back to the "interval time in counter mode" parameter.
The PAUSE LED flashes.
4
Press briefly.
(select the parameter)
The current value for the interval time is displayed.
Example: 24 pulses
The PAUSE LED flashes.
5
Press repeatedly until the
desired value is set.
The new value is displayed.
Example: 36 pulses
The PAUSE LED flashes.
6
Press briefly.
(confirm the new value)
Display the next parameter.
Example: Contact time in timer mode
The CONTACT LED flashes.
The new value for the "interval time" parameter has been confirmed and stored in the control
unit's non-volatile memory.
7
Press longer than 3 s.
The display clears.
A new lubrication cycle is started beginning with the interval time.