44
<
WARNING
Before addressing the following malfunctions, turn off the power from the control and pumping
centre. Turn off the compressed air supply by lifting up the shut
-off valve button (Fig. 8, pos. e).
Remove pressure from the grease filter before opening it with
the bleed screw located in the
filter plug (Fig.
8, pos. 11). Any residual pressure in the system when opening or disconnecting
components may cause components to be thrown or lubricant to spray, causing injury to people
or damage to the environment.
Description of malfunction Cause of malfunction Solution
The pump starts but pressure does not
increase.
The grease filter is clogged.
There is air in the suction piping.
There are impurities in the pump’s
suction inlet.
Clean or replace the grease filter
cartridge.
Bleed the pump by opening the grease
filter bleed screw ( Fig. 8, pos. 11) or the
pump’s pressure connection (P). Check
that only grease and no air comes out of
the bleed screw or the pressure
connection.
Contact Oy SKF Ab.

Table of Contents

Other manuals for SKF MAX-1-2-230-IF105-R-V2

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SKF MAX-1-2-230-IF105-R-V2 and is the answer not in the manual?

SKF MAX-1-2-230-IF105-R-V2 Specifications

General IconGeneral
BrandSKF
ModelMAX-1-2-230-IF105-R-V2
CategoryWater Pump
LanguageEnglish

Related product manuals