48
9. Maintenance
Cleaning
9.1.1 Basics
Cleaning should be carried out in accordance with the operator's own company rules, and cleaning agents and devices
and the personal protective equipment to be used should likewise be selected in accordance with those rules. Only
cleaning agents compatible with the materials may be used for cleaning. Completely remove any cleaning agent residue
left on the product and rinse with clear water. Unauthorized persons must be kept away. Use signage to indicate wet
areas.
9.1.2 Interior cleaning
The interior normally does not need to be cleaned. The interior of the product must be cleaned if incorrect or contaminated
lubricant accidentally enters the product. Please contact our Service department.
9.1.3 Exterior cleaning
Do not allow any cleaning fluid to enter the interior of the product during cleaning.
Risk of fatal electric shock
Cleaning work may only be performed on products that have been de-energized first. When
cleaning electrical components, be mindful of the IP enclosure rating.
Serious injury from contact with or inhalation of hazardous substances
Wear personal protective equipment. Observe the safety data sheet (SDS) of the hazardous
substance.
Avoid contaminating other objects or the environment during cleaning.
Periodic inspections
Monthly inspections
" Inspect the pressure air regulator and drain it of water
" Check the pump’s operation.
" Check the pump and lubrication system for leaks.
When replacing the barrel (in addition to the above):
" Clean the grease filter and the filter cartridge and replace them if necessary.