51
SJ12 E, SJ16 E, SJ20 E
243762ABA
Section 5 – Operation
WARNING
Do not operate this MEWP without authorization
and training. If you do not obey, there is a risk of
death or serious injury.
Do these tasks in sequence before MEWP operation:
1. Worksite inspection. Refer to Section 2.4.
2. Visual and daily maintenance inspections. Refer
to Section 4.2.
3. Function tests. Refer to Section 4.3.
4. If a risk assessment nds that a rescue plan
is necessary, make sure you have a system of
communication. The communication must be
between the personnel on the platform and
the selected support personnel. The selected
support personnel must know how to use the
base controls to lower the platform.
WARNING
Do not operate the MEWP if:
It does not operate correctly
It is damaged or shows worn or missing parts
The safety devices are tampered with or
disabled
It is locked and tagged for servicing or repair
It was modied without permission from
Skyjack and the MEWP owner.
If you do not obey, there is a risk of death or
serious injury.
5.1 Energize the base control
console
1. Turn the main power disconnect switch to the
on position.
2. Pull the emergency-stop button on the base
control console.
3. Turn and hold the off/platform/base key switch
in the base position.
5.2 Raise or lower the
platform with the base
control console
1. Energize the base control console (refer to
Section 5.1).
2. Turn and hold the off/platform/base key switch
in the base position.
WARNING
Look for overhead obstructions or other possible
hazards around the MEWP when you raise the
platform. Do not lower the platform unless the area
below is clear of personnel and obstructions. If
you do not obey, there is a risk of death or serious
injury.
3. Turn and hold the lower/neutral/raise switch in
the raise or lower position to raise or lower the
platform. Release the switch to stop.
5.3 Energize the platform
control console
1. Turn the main power disconnect switch to the
on position.
2. Pull the emergency-stop button on the base
control console.
3. Turn the off/platform/base key switch in the
platform position.
WARNING
Fall hazard. Use the three points of contact
principle when you use the MEWP to enter or exit
the platform. If you do not obey, there is a risk of
death or serious injury.
4. Enter the platform.
5. Close the gate.
6. Pull the emergency-stop button on the platform
control console.