SLAYER STEAM LP USER MANUAL V1.1 | JUNE 2019 26
Brew Parameter Adjustments
The Slayer Steam LP has options for two programmable volumetric
settings per group.
Steam LP also has multiple settings available for adjustment per shot.
These are:
Pre-Infusion time, tunable in tenth of a second (0.1s) increments
Brew Weight, tunable in half-gram (0.5g) increments
Post-Infusion Weight, tunable in half-gram (0.5g) increments
To Program Shot 1, follow the steps below.
1. From the Manager Menu, scroll to Brew Parameters and press the
button to select.
2. Select <Shot1> and press the menu button to advance.
3. For the Group parameter, select the option <Group1> or scroll to <All>
to save the Shot 1 profile to all groups. Depress the menu button to
accept.
SCREEN EXAMPLE:
Position Group
<Shot1> Gp1
4. The settings for each phase of the shot profile - Pre, Brew, and Post -
are now displayed and ready for adjustment. Press the menu button
to accept the displayed value or scroll to adjust. Pressing the menu
button advances the prompt. Once all three settings have been
accepted, the shot is saved as Shot1 for that group (and to All groups
if previously selected).
Pre Brew Post
<0.0>s 30.0g 0.0g
5. The screen will revert to the Manager Menu Options
6. The process can be repeated for Shot 2 on Group1 and for each Shot
position on Group 2 and Group 3.
NOTE: If there is a 1-3 gram dierence in the final output of your group
heads volumetrics and proper technique has been used for dialing in a
shot (ie; using a scale and an exacting coee recipe), verify the machine
flowmeters are calibrated. For a step by step guide toward calibrating your
flowmeters for optimum consistency, turn to pg. 32.
Brew Group Temperature
Brew tank temperatures are measured in real-time at each group head
and displayed in degrees Fahrenheit or Celsius, depending on saved
preference. Adjustable in tenth-degree (0.1-degree) increments
• 82° C (180° F) Minimum to 97° C (206° F) Maximum
SCREEN EXAMPLE:
Temperature
<201>F
1. Working from the left group will enables the ability to copy the
temperature to all groups.
2. Copy all Groups < YES > prompt will only occur when programming
values with the Master (Left) group. By selecting NO, proceed by
individually programming brew group temperatures as desired.
3. Exit the menu when programming is completed across all groups
Hot-Water Tap, Steam Boiler Pressure and Reset Counters
Please see the sections in Machine Calibrations (pg 31)
Auto-Flushing
Steam LP features an Auto Flush that enables a quick purge of the group
after each shot for a programmable time period between zero and five
seconds. This feature can also be set to <O>
From the Manager Menu, scroll to Auto Flush, and depress the menu
button to select.
SCREEN EXAMPLE:
Auto Flushing
<Auto+Man> 5.0s
The mode selection options are Auto, Manual, Auto + Manual, and O.
If Auto is selected, the group will flush for the pre-set time whenever the
paddle is moved back to the home position after a completed shot. This
setting is operable when the Steam LP is making shots in Automatic Mode
If Manual is selected, the flush function is only activated when the paddle
is rapidly moved away from and returned to the home position. The
duration of the move needs to complete in less 0.5 seconds to activate the
flush.
When Auto+Man is selected, the group will autoflush for the set amount
of time using either of the above methods.
This is the paddle position
for parameters saved as
“Shot 2”
This is the paddle position
for parameters saved as
“Shot 1”