SLAYER STEAM LP USER MANUAL V1.1 | JUNE 2019 33
ADVANCED MENU, PASSWORD PROTECTED OPTION
The second level of navigation is the Advanced Menu, and is a
continuation of the Manager Menu higher level access to critical settings
and Preventative Maintenance services done by a Slayer certified
technician. We have intentionally removed the password for this section
for ease of setup but recommend you password protect to remove the
potential for unintentional reboots and adjustments without the proper
calibration tools or knowledge base. The list below showcases the
extended menu with Advanced programming options.
While navigating the Home menu, access the Advanced Menu by scrolling
to the “Password” title screen and entering < > leave the value blank if
visiting for the first time. To program both the Manager and Advanced
Menu password, visit the instructions on page 22.
Do not interact with the Advanced Menu before reading this manual
in its entirety. Then – if unsure – consult your Slayer representative,
reseller, or qualified service personnel.
ADVANCED MENU OPTIONS
1. Service Notification
2. Brew Parameter Adjustments
3. Brew Group Temperature
4. Hot water Tap Program Dose
5. Steam Boiler Pressure
6. Totals Reset
7. Auto-Flushing
8. Calibrate Shot Weight Osets
9. Heater Control Element ON/OFF
10. Temperature C / F
11. Shot Light Brightness
12. Lifetime Count
13. Set Time/Date
14. Times for Power Save to Begin
15. Times for Power Save to End
16. Service Notification (Reset)
17. Passwords (Reset)
18. Brew Temp Oset
19. Post-Brew Vent
20. Auto-Fill Delay
21. Flowmeter Calibration
The basic Manager Menu only displays the first eight options.
HEATING ELEMENTS ON/OFF
This menu allows for individual boilers both brew and steam to be turned
ON or OFF.
1. Scroll to the Passwords title screen press and type in the password for
the Advanced Menu.
2. The option to adjust ALL heating elements ON/ OFF, universally, will
be presented.
3. Rotate the menu button to cycle between “On” and “O”.
4. Press and release the menu button to confirm your new setting and
proceed to the next step.
5. Repeat steps 4-5 for all remaining settings:
Gp1 (heating element for leftmost brew tank)
Gp2 (on 2-group, right brew tank; on 3-group, middle brew tank)
Gp3 (rightmost brew tank; 3-group only)
Stm (steam tank)
6. Long press and hold the button to save and exit
TEMPERATURE °C / °F (SELECTION)
All temperatures displayed can be shown in either Celsius or Fahrenheit.
Once selected this readout will be visible across brew and steam tanks.
To adjust the temperature readout in °C or °F follow the details below.
1. Scroll to the Password title screen, select and enter code for the
Advanced Menu.
2. Rotate the menu button clockwise until the “Temperature” setting
appears.
3. Press and release again to enter the “Temperature” setting. The option
to adjust the unit of temperature measurement will be presented.
4. Scroll to cycle between “F” (Fahrenheit) and “C” (Celsius).
5. Press and hold the menu button to save and exit
To adjust the boiler temperatures, see instructions under Using Slayer >
Adjust Brew Tank Temperature in the Manager menu on pg. 26.