SLAYER STEAM LP USER MANUAL V1.1 | JUNE 2019 32
CALIBRATING SHOT WEIGHT OFFSETS
Using volumetrics, Slayer Steam LP uses osets to account for water
absorbed by coee during extraction.
It is recommendedto use this feature any time you change coee,
grind setting, or dose.
It is also recommended when dialing in the oset during daily
setup or shift change as it is very easy to adjust osets on the fly
by periodically measuring shot output weights with a scale
Using osets are an eective way to ensure accurate and consistent shots.
This feature is accessible through more than one menu for convenience.
1. Follow the Steps under the PREPARE ESPRESSO section on pg. 28
or prepare a shot in Manual Mode with any desired method, using a
scale to measure shot weight
2. When the shot is complete, press the Manual Mode Button
SCREEN EXAMPLE
Save Last Shot
No Yes All <CalWt>
3. Scroll to <CalWt> and press the menu button to enter
4. The screen value defualt is 30.0g. Scroll to adjust this value to the
nearest 0.5 g of the value on the scale for the shot. Press the menu
button to accept.
SCREEN EXAMPLE
Measured Wt: <30.0>g
5. The screen will return to the previous set of options for saving and
copying the shot if desired. Or press and hold the menu button to
save and exit to the home screen.
SHOT WEIGHT OFFSET CALIBRATION (ALTERNATE PROCEDURE)
1. Prepare and complete a saved shot (Shot 1 or Shot 2) using a scale to
measure total shot weight.
2. From the Home screen, scroll to Enter Password to access the
Manager Menu
3. Scroll to “Cal Shot Wt Oset” and press the button to enter
4. Scroll to choose and press to accept both the Group position and Shot
number that was just measured.
5. The screen will display the expected weight of the shot.
SCREEN EXAMPLE
Expected Wt: 53.5g
Measured Wt: <53.5>g
6. Scroll to enter the reading on the scale as the measured weight to the
nearest 0.5 gram.
7. Press and hold the menu button to save and exit.