- 95 -
No.EX##-OMY0004
Error Codes for Parameter Errors
0x04CX
1216dez
1217dez
1218dez
1219dez
The least significant four bits
display information on the
affected output.
Range of values:
0: M
1: Zone Z1
2: Zone Z2
3: Zone Z3
At least one value of
the parameter data
regarding the
feedback monitoring is
outside the permitted
range of values.
Correct value and resend the parameter data to the
device.
0x04DX
1232dez
1233dez
1234dez
1235dez
The least significant four bits
display information on the
affected output.
Range of values:
0: M
1: Zone Z1
2: Zone Z2
3: Zone Z3
In the case of an
activated feedback
monitoring the relevant
input(s) must be
occupied.
Correct value and resend the parameter data to the
device.
0x030X
768dez
769dez
770dez
771dez
The least significant four bits
display information on the
affected input.
Range of values:
0: IN0, IN4
1: IN1, IN5
2: IN2, IN6
3: IN3, IN7
The parameter sensor
evaluation for the input
pair displayed is
outside the permitted
range.
Correct value and resend the parameter data to the
device.
0x031X
784dez
785dez
786dez
787dez
792dez
793dez
794dez
795dez
The least significant four bits
display information on the
affected input.
Range of values:
0: IN0
1: IN1
2: IN2
3: IN3
8: IN4
9: IN5
A: IN6
B: IN7
The filter time setting
for the displayed input
is outside the
permitted range.
Correct value and resend the parameter data to the
device.
0x032X
800dez
801dez
802dez
803dez
808dez
809dez
810dez
811dez
The least significant four bits
display information on the
affected input.
Range of values:
0: IN0
1: IN1
2: IN2
3: IN3
8: IN4
9: IN5
A: IN6
B: IN7
The clock allocation
for the displayed input
is outside the
permitted range.
Input parameter regarding the clock allocation is
not permitted.
Correct value and resend the parameter data to the
device.