Parameter Settings List
The IP8101 smart positioner operates at settings suitable for various applications by changing
the setting parameters
1
. Table 3 shows the main positioner functions which can be changed. For
details of the setting parameters, refer to Parameter Code Detail.
Setting parameters
Description
Remarks
(000) Actuator type
Changes the type of actuator (available for rotary actuators)
Not available
to user
(200) Operation direction
Changes the operation direction between direct or reverse.
-
(300) Split range
Changes between split range and non-split range.
-
(400) Zero point / span
Changes the actuator opening at input current 0% and 100%
respectively.
-
(500) Forced fully close
/ fully open
Changes the input current to open or close the actuator fully with
increased force.
Set to ON (fully closed = 0.5% and fully open = 99.5%) at the
time of factory shipment.
-
(600) Dead band
Changes the deviation where the dead band is applied.
-
(700) Valve opening
characteristics
Changes the valve opening characteristics by selecting linearity,
equal%, quick open or user settings.
-
(800) PID constant
Changes the controlling performance of the positioner.
-
(900) Alarm 1
Changes the actuator opening which receives alarm output 1.
Available as
an option
(A00) Alarm 2
Changes the actuator opening which receives alarm output 2.
Available as
an option
(b00) Analog output
Changes the analog output type between proportional and
reversal outputs.
Available as
an option
(C00) Calibration
Provides zero point / span adjustment, automatic PID constant,
balance current adjustment and input current calibration.
-
1: Change of dead band (parameter code: 600) or valve characteristics (parameter code: 700) may prevent
the positioner from satisfying the Specifications”.
Table 3

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SMC Networks IP8101 Series and is the answer not in the manual?

SMC Networks IP8101 Series Specifications

General IconGeneral
BrandSMC Networks
ModelIP8101 Series
CategoryValve Positioners
LanguageEnglish

Related product manuals