-10-
No.PF※※-OMA1002
Adjustment and operation
•Connect the load before turning the power supply on.
•Do not short-circuit the load.
•Confirm that the fluid is flowing in the pipe when controlling the flow rate.
If there is no supply pressure, a current beyond the product specifications may flow in the event of an error in control
action.
•If the controlled flow rate does not continuously reach the commanded flow rate for at least 5 seconds, it
will result in a control error and the flow control will stop.
•Do not touch the LCD during operation.
The display can vary due to static electricity.
•When the product is not energized, the valve is fully closed (normally closed (N.C.)).
•Do not supply a pressure that is higher than that in the IN side to the OUT side.
Otherwise, the control valve will open, causing the fluid to flow backward.
Maintenance
•Perform regular maintenance and inspections.
There is a risk of unexpected failure of components due to the malfunction of equipment and machinery.
•Before performing maintenance, turn off the power supply, stop the air supply, exhaust the residual
compressed air in the piping, and verify the release of air.
Otherwise, unintended malfunction of system components can result.
•Remove the condensate periodically.
If condensate enters the OUT side, it can cause operating failure of pneumatic equipment.
•Do not use solvents such as benzene, thinner, etc. to clean the product.
This may damage the surface of the body or erase the markings on the body.
Use a soft cloth to remove stains.
For heavy stains, use a damp cloth soaked with diluted neutral detergent and fully squeezed, then wipe up the
stains again with a dry cloth.