13
EEWB334A
4-13
B
B
20
1817
A
A
BA
15
16
19
BALANCING Balancing Screen
Fig. 4-13
15A START key (starts the run)
- Starts the measuring run. Press to start wheel rota-
tion, with the wheel guard down.
15B STOP key
- Immediately stops a wheel run already started.
16 SPLIT key
- Selects (A) or deselects (B) the option to hide the
weight behind the spokes.
17 SPOKES key
– Each selection increases the number of spokes set
by one (from 3 to 15 spokes).
18 OPT/MIN key
– Accesses the Optimisation / Minimisation screen.
19 END key
- Activates the reading of the residual imbalances.
The operation of the key is timed and it automatically
returns to the basic display.
20 Key g / oz
- Enables the readings in grams (A) and ounces (B).