HYD 5/6/8/10/15/20KTL-3PH USER MANUAL
99
inverter, switch
OFF inverter, wait
for 5 minutes, then
switch ON inverter.
Check whether the
problem is solved.
If no, please
contact technical
support.
ID013
RefluxFault
Feed-in Limit
function is faulty
ID014
VGridUnbalance
unbalanced
source voltage
ID015
InvOVPInstant
The inverter
instantaneous
value overvoltage
ID016
GridPhaseMutatio
n
Abrupt change
of grid phase
ID017
HwADErrIGrid
Power grid
current sampling
error
ID018
HwADErrDCI(AC)
Wrong sampling
of dc component
of grid current
ID019
HwADErrVGrid(DC
)
Power grid
voltage sampling
error (DC)
ID020
HwADErrVGrid(AC
)
Power grid
voltage sampling
error (AC)
ID021
HwGFCIFault(DC)
Leakage current
sampling error
(DC)
ID022
HwGFCIFault(AC)
Leakage current
sampling error
(AC)
ID023
HwADErrDCV
Error in dc
component
sampling of load
voltage
ID024
HwADErrIdc
DC input current
sampling error
ID025
HwADErrDCI(DC)
DCI Sampling
Error (DC)
ID026
HwADErrIdcBranc
h
The branch
current is
incorrectly
sampled
ID027
PVLowImpedance
PV- Low ground
impedance
ID028
PIDAbnormalOut
PID abnormal
output