HYD 5/6/8/10/15/20KTL-3PH USER MANUAL
Press Up button again to show Battery
Information(BAT1) like current, power, state of
charge etc.
Press Up button again to show Battery
Information(BAT2) like current, power, state of
charge etc.
7.3 Energy storage modes
The HYD 5/6/8/10/15/20KTL-3PH comes with several integrated
energy management modes.
7.3.1 Self-use Mode
In the Self-use mode, the inverter will automatically charge and
discharge the battery according to the following rules:
If PV generation equals the load
consumption (ΔP < 100 W), the
inverter won't charge or
discharge the battery
If PV generation is larger than
the load consumption, the
surplus power is stored in the
battery
If the battery is full or at
maximum charging power, the
excess power will be exported to
the grid