HYD 5/6/8/10/15/20KTL-3PH USER MANUAL
81
If the PV generation is less than
the load consumption, it will
discharge the battery to supply
power to the load.
If PV generation plus Battery
discharge power is less than the
load, the inverter will import
power from the grid.
The priority of power supply: PV, Battery, Grid
The priority of power consumption: Loads, Battery, Grid
NOTE
If it is not allowed to export power to the grid, an
smart meter and/or CT needs to be installed, and the
"feed-in limit” function needs to be enabled.
7.3.2 Time-of-Use Mode
Set Time-of-use Mode
Rule 0:
Enabled / Disabled
From
To
SOC
Charge
02h00m -
04h00m
070%
01000W
Effective
date
Dec.22
-
Mar.21
Weekday
select
Mon. Tue. Wed. Thu. Fri. Sat. Sun.
If no rule applies, the Self-use Mode is active.