HYD 5/6/8/10/15/20KTL-3PH USER MANUAL
Settings - Switch On/Off- Switch On. start up to enable the
inverter to start up and run.
3. Disconnect the AC circuit breaker connecting the inverter
power grid port to the power grid.
4. Disconnect the AC breaker connecting the inverter load
port to the emergency load.
5. Disconnect the PV side DC switch.
6. Turn off the battery and disconnect the DC switch between
the battery and the inverter.
7. Wait for 5 minutes before checking the inverter.
8.1.2 Earth fault alarm
This inverter is compliant with IEC 62109-2 Clause 13.9 and
AS/NZS 5033 for earth fault protection.
If an earth fault alarm occurs, the error is displayed on the LCD
screen, the red light illuminates and the error can be found in
the error history log.
When the inverter is connected to the battery system, when the
battery system has ground fault/leak alarm in accordance with
AS/NZS 5139, the inverter will also alarm. The alarm method is
the same as above.
In the case of devices equipped with a stick logger,
the alarm information can be viewed on the monitoring
portal and retrieved via the smartphone app.
8.2 Error list
The voltage of
the power grid is
too high
If the alarm occurs
occasionally, the
possible cause is
that the electric
grid is abnormal
occasionally.
The voltage of
the mains is too
low