HYD 5/6/8/10/15/20KTL-3PH USER MANUAL
115
9 DataSheet
NOTE
The following parameters may change without notice,please refer to
the user manual and DataSheet on our website.
Model
HYD
5KTL-3PH
HYD
6KTL-3PH
HYD
8KTL-3PH
HYD
10KTL-3PH
HYD
10KTL-3PH-A
HYD
15KTL-3PH
HYD
20KTL-3PH
PV input
Recommended Max. PV
Power
7500Wp
9000Wp
12000Wp
15000Wp
15000Wp
22500Wp
30000Wp
Max. Input Voltage
1000Vd.c.
Start-up Voltage
200Vd.c.
Rated Input Voltage
600Vd.c.
MPPT Operating Voltage
Range
180-960 Vd.c.
Number of MPPT
2
Max. Number of Input
Strings per MPPT
1/1
2/2
Max. Input Current [1]
16A/16A
32A/32A
Max. Isc[2]
22.5A/22.5A
45A/45A
AC Output (Grid)
Rated Output Power
5 kW
6 kW
8 kW
10 kW
10 kW
15 kW
20 kW
Rated Output Current
7.6/7.2/6.9A
9.1/8.7/8.3A
12.1/11.6/11.1A
15.2/14.5/13.9A
15.2/14.5/13.9A
22.7/21.7/20.8A
30.3/29.0/27.8A
Rated Output Voltage
3(N)~+PE, 380/400/415 Va.c.
Rated Output Frequency
50/60Hz
Max. Apparent Power
5.5 kVA
6.6 kVA
8.8 kVA
11 kVA
10 kVA
16.5 kVA
22 kVA
Max. Output Current
8.3/8.0/7.6A
10.0/9.6/9.2A
13.3/12.8/12.2A
16.7/15.9/15.3A
15.2/14.5/13.9A
25.0/23.9/22.9A
33.3/31.9/30.6A
THDi
<3%
Power Factor Range
0.8 lagging-0.8 leading
Battery
Battery Type [3]
Lithium-ion & Lead-acid
Voltage Range
180-800 Vd.c.
Number of Battery Input
Channels
1
2
Max. Charging Power
5 kW
6 kW
8 kW
10 kW
10 kW
15 kW
20 kW
Max. Discharging Power
5 kW
6 kW
8 kW
10 kW
10 kW
15 kW
20 kW
Max. Charging Current
25 A
25 A
25 A
25/25 A
25/25 A
25/25 A
25/25 A
Max. Discharging Current
25 A
25 A
25 A
25/25 A
25/25 A
25/25 A
25/25 A
BMS Communication
CAN/RS485
AC Output (Backup)
Rated Output Power
5 kW
6 kW
8 kW
10 kW
10 kW
15 kW
20 kW