HYD 5/6/8/10/15/20KTL-3PH USER MANUAL
101
repaired in time.
ID043
PEConnectFault
Earth fault
Check the PE
conductor for
function
ID044
InputConfigError
Incorrect input
mode
configuration
Check the input
mode
(parallel/independ
ent mode) Settings
for the inverter. If
not, change the
input mode.
ID045
CTDisconnect
CT error
Check that the
wiring of the
current
transformer is
correct.
ID046
ReversalConnect
The battery is
connected
reversedly
Check whether the
battery wiring is
correct.
ID047
ParallelFault
Master does not
exist or is
duplicate
Check the parallel
mode settings for
the inverter. Check
whether the wiring
is correct.
ID048
SNTypeFault
Serial number
fault
Internal faults of
inverter, switch
OFF inverter, wait
for 5 minutes, then
switch ON inverter.
Check whether the
problem is solved.
If no, please
contact technical
support.
ID049
TempErrBat
Battery
temperature
error
For Inner BMS
battery, make sure
that the battery
NTC cable is
properly
connected. Make
sure the inverter is
ID050
TempErrHeatSink
1
Temperature
error heat sink 1
ID051
TempErrHeatSink
2
Temperature
error heat sink 2