HYD 5/6/8/10/15/20KTL-3PH USER MANUAL
103
voltage of the
inverter. If this is
the case, adjust
the number of PV
modules in series.
After the
correction, the
inverter
automatically
returns to its
normal state.
ID070
BatOVP
Battery
overvoltage
Check whether the
voltage of the
battery is higher
than the
maximum input
voltage of the
inverter. If this is
the case, adjust
the number of
battery modules in
series.
ID071
LLCBusOVP
LLC Bus
overvoltage
protection
Internal error of
the inverter.
Switch off the
inverter, wait 5
minutes and then
switch the unit on
again.
If the error persists,
contact technical
support.
ID072
SwBusRmsOVP
Inverter bus
voltage RMS
Software
overvoltage
ID073
SwBusIOVP
Inverter bus
voltage
instantaneous
Software
overvoltage
ID074
FlyingCapOVP
Flying trans-
capacitor
overvoltage
protection