HYD 5/6/8/10/15/20KTL-3PH USER MANUAL
106
ID113
OverTempDeratin
g
The inverter has
throttled due to
too high a
temperature
Make sure that the
inverter has been
installed in a cool
and well-
ventilated place
without direct
sunlight.
Make sure the
inverter is installed
vertically and the
ambient
temperature is
below the
temperature limit
of the inverter.
ID114
FreqDerating
AC frequency is
too high
Make sure that the
mains frequency
and voltage are
within the
permissible range.
ID115
FreqLoading
AC frequency is
too low
ID116
VoltDerating
AC voltage is too
high
ID117
VoltLoading
AC voltage is too
low
ID118
LowTempDerating
Low temperature
load reduction
ID121
SpdFail(DC)
Lightning
Protection
Failure (DC)
ID122
SpdFail(AC)
Lightning
Protection failure
(AC)
ID124
BatDchgProhibit
No battery
protection
Please check if the
battery voltage of
the inverter is too
low.
ID125
BatLowVoltShut
Low battery
voltage
shutdown
ID129
PermHwAcOCP
Mains current is
too high and has
caused an
unrecoverable
hardware fault
Internal error of
the inverter.
Switch off the
inverter, wait 5
minutes and then
switch the unit on
again.
If the error persists,
ID130
PermBusOVP
Bus voltage is too
high and has
caused a non-