HYD 5/6/8/10/15/20KTL-3PH USER MANUAL
108
support.
ID140
PermRelayFail
Permanent error
of the mains
relay
ID141
PermBusUnbalan
ce
The bus voltage
is unbalanced
and has caused
an unrecoverable
error
ID142
PermSpdFail(DC)
surge protection
ID143
PermSpdFail(AC)
surge protection
ID144
PermGridRlyFail
Grid relay fault
ID145
USBFault
USB error
Check the USB
connection of the
inverter.
ID146
WifiFault
Wifi error
Check the
inverter's WiFi
connection.
ID147
BluetoothFault
Bluetooth error
Check the
Bluetooth
connection of the
inverter.
ID148
RTCFault
RTC clock failure
Internal error of
the inverter.
Switch off the
inverter, wait 5
minutes and then
switch the unit
back on.
If the error persists,
contact technical
support.
ID149
CommEEPROMFa
ult
EEPROM error of
the
communication
card
ID150
FlashFault
Communication
card FLASH error
ID152
SafetyVerFrauIt
ID153
SCILose(DC)
SCI