HYD 5/6/8/10/15/20KTL-3PH USER MANUAL
110
Communication
is faulty
ID160
BMS4CommFault
Lithium battery 4
Communication
is faulty
ID161
ForceShutdown
Forced shutdown
The inverter has
been forcibly
disconnected.
ID162
RemoteShutdown
Remote
shutdown
The inverter is shut
down remotely.
ID163
Drms0Shutdown
DRM 0 shutdown
The inverter is
running with a
Drms0 shutdown.
ID164
PSCommFault
Power station
communication
failure shut down
ID169
FanFault1
Fan 1 fault
Check if the
corresponding fan
of the inverter is
running normally.
ID170
FanFault2
Fan 2 fault
ID171
FanFault3
Fan 3 fault
ID172
FanFault4
Fan 4 fault
ID173
FanFault5
Fan 5 fault
ID174
FanFault6
Fan 6 fault
ID175
FanFault7
Fan 7 fault
ID177
BMS OVP
BMS overvoltage
alarm
Internal error in
the connected
lithium battery.
Switch off the
inverter and the
lithium battery,
wait 5 minutes
and then switch
the components
on again.
If the error persists,
contact technical
support.
ID178
BMS UVP
BMS
Undervoltage
alarm
ID179
BMS OTP
BMS High
temperature
warning
ID180
BMS UTP
BMS low
temperature
warning
ID181
BMS OCP
BMS overload
warning during
charging and
discharging
ID182
BMS Short
BMS Short circuit
alarm
Please contact
technical support.