HYD 5/6/8/10/15/20KTL-3PH USER MANUAL
42
Table. 5-5 CT 200 A/5 A Default
(Split Core Current Transformer for smart meter or as a CT directly
connected to the inverter.)
Technical Data
Rated primary current
200 A
Rated secondary
current
5 A
Rated operating
frequency
50/60 Hz
Perforated size
24 mm Diameter
Table. 5-6 Smart Meter through CTs
Technical Data
Voltage
AC 3×230/400 V
Current
1.5(6) A
Frequency
50/60 Hz
Pulse
6400 imp / kWh
Power accuracy
Active Class 0.5S, Reactive Class 2
Table. 5-7 Directly connected Smart Meter
Technical Data
Voltage
AC 3×230/400 V
Current
5(80) A
Frequency
50/60 Hz
Pulse
400 imp / kWh
Power accuracy
Active Class 1, Reactive Class 2