Line Level Input/Outputs
All other analogue inputs and outputs can be connected via a patchbay. It is recommended that the cable shield
is connected at the console end and disconnected at the patch row to avoid ground loops. Wiring to the
installation should normally have the shield connected to the patch row. The shield connection of all jacks
should be linked together (note that patch rows with solid metal front panels will automatically do this) and then
linked to a common star point on the patchbay. This starpoint can then be returned – via a thick grounding
cable (6mm sq. or greater) – to the chassis stud on the rear of the AWS 900+ console. This will reduce the risk
of earth loops within the installation.
Note that the shields of all analogue inputs and outputs other than the microphone inputs are connected
directly to the chassis of the AWS900+.