Manual Integrator Supercal 531 06-06-2011 67
Module RS-232 with two relay outputs (see 6.2.3)
RS-232:
Baud rate 300..38'400 baud
Data transmission full duplex
Protocol M-Bus acc. to EN 1434 (half-duplex)
Relays:
Outputs 2
Max. switching voltage, peak 60 V AC/DC
Max. constant current 400 mA
Surge current (100 ms) 1'000 mA
Max. power dissipation 500 mW
Max. forward resistance 2,5
Typical output capacitance 150 pF
Max. frequency 100 Hz
Pulse duration 5..400 ms possible in steps of 1ms
Error status closed (no error)
Alarm condition open (no alarm)
Connection diagram:
63 64 62
RxD
TxD
GND
RS-232
80
(84)
Relais
Output
Relais
Output
81
(85)
82
(86)
83
(87)
+
-
-+
TIA-574 9-pol
1
6
Module RS-232 (see 6.2.4)
Baud rate 300..9’600 baud
Data transmission full-duplex
Protocol M-Bus acc. to EN 1434 (half-duplex)
Connection diagram:
63 64 62
RxD
TxD
GND
RS-232
TIA-574 9-pol
1
6
Combined module with RS-232, three relay outputs, four freely programmable outputs
0...20 mA, 4..20 mA or 0..10 VDC (see 6.2.5)
RS-232: acc. to specification RS-232 module with two relay out-
puts
Relay: acc. to specification relay module
Analogue: acc. to specification analogue module with two outputs
0..20 mA, 4..20 mA or 0..10 VDC
Analogue inputs 4 (external voltage supply)
Analogue outputs 4