6-11
6-6. MECHA AGING
When [3] is selected on this test mode screen, the machine enters
the mechanical aging mode. The following screen appears. Do
not use this mode.
### Mecha Aging ###
1.Please Select Aging mode
2.All Mecha : random Aging mode
3.All Mecha : + 1 Move
4.All Mecha : – 1 Move
5.All Mecha : 1 Disc Front
6.All Mecha : 1 Disc Rear
7.TurnTable : Random Move
8.TurnTable : Half Move
9.Door Open/Close
Exit:Return
6-7. EMERGENCY HISTORY
### MEG. History ###
Laser Hours CD xxxxxxxh
DVD xxxxxxxh
1. 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00
2. 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00
Select: 1 – 9 Scroll: UP/DOWN
(1: Last EMG.) Exit: Return
On the Test Mode Menu screen, selecting [4] displays the infor-
mation such as servo emergency history. The history information
from last 1 up to 10 can be scrolled with ↑ key or ↓ key. Also,
specific information can be displayed by directly entering that
number with ten keys.
The upper two lines display the laser ON total hours. Data below
minutes are omitted.
Clearing History Information
Clearing laser hours
Press [DISPLAY] and [CLEAR] keys in this order.
Both CD and DVD data are cleared.
Clearing emergency history
Press [TITLE] and [CLEAR] keys in this order.
Initializing set up data
Press [DVD] and [CLEAR] keys in this order.
The data have been initialized when “Set Up Initialized” mes-
sage is displayed. The EMG. History screen will be restored
soon.
When [PAUSE] is selected in the 300CHG Mecha Con Menu-2
## Turn Table Offset Debug ##
NO | On | Off
1|X|XX
2|X|XX
3|X|XX
4|X|XX
5|X|XX
PLAY : Slow Turn (No.5)
STOP : Turn Stop
PAUSE : Change PWM
RETURN:Exit
[PLAY] : Moves the T. table slowly,
[STOP] :Stops movement of the T. table.
[PAUSE]: Sets the PWM value in the order starting from NO →
On → Off.
This mode is prepared for measurement of the load to
the T. table as described before. Result of the measure-
ment is not reflected on adjustment. After this mode is
selected, Mecha Initial must be performed.

Table of Contents