Memory and SetupST700 Dash Display System
56
Speed and odoPress and turn the control to choose between using
MPH and miles or Km/h and kilometres for the displays of speed
and odometer distance.
Sensor Input 1 and Sensor Input 2The ST700 Dash Display Sys-
tem can display measurements made by up to two Stack sensors fit-
ted to the vehicle. The information from these sensors appears on
one of the display layers (see page 34). Press the rotary control
briefly to set Sensor 1 or Sensor 2 to the correct measurement type.
Refer to Table 2 on page 23 and Table 4 on page 25 respectively for
the compatible types of Stack pressure and temperature sensors.
For each channel, set the measured parameter and then turn the ro-
tary control to select the sensor type fitted and the units that the sys-
tem will use to display the measurements.
You may also set the alarm type for each measured channel. Select
disabled if you do not wish to set an alarm on a channel.
Set ‘Above’ to display a pop–up alarm when the measured condition
goes above the threshold setting that you define (for example, when
you monitor water temperature).
Set ‘Below’ to display a pop–up alarm when the measured condition
goes below the threshold setting that you define (for example, when
you monitor oil pressure).
Set a threshold value for the alarm setting. The option to set a threshold
will not be available if you have disabled the alarm feature.