TUP500 Series Product Specifications
14-11
14.6. MSW5
Bit Function OFF/“0” ON/“1” Emulation Note
SL SP EP
F Snout LED control (See table below) *4
E Snout LED control (See table below) *4
D
C
B
A
9
8
7 Presenter Paper Auto-recovery Time (See table below) *1
6 Presenter Paper Auto-recovery Time (See table below) *1
5 Presenter Paper Auto-recovery Time (See table below) *1
4 Presenter Paper Auto-recovery Time (See table below) *1
3 Presenter Paper Auto-recovery Time (See table below) *1
2 Presenter Paper Auto-recovery Time (See table below) *1
1 Presenter Paper Auto-recovery Time (See table below) *1
0
Presenter Paper Auto-recovery Time (See table below) *1
*1) Details for Presenter Paper Auto-recovery Time
n MSW5-7 MSW5-6 MSW5-5 MSW5-4 MSW5-3 MSW5-2 MSW5-1 MSW5-0 Auto-recovery Time
“00” 0 0 0 0 0 0 0 0 Auto-recovery Invalid
(Default)
“01” 0 0 0 0 0 0 0 1 for 0.5 seconds
“02” 0 0 0 0 0 0 1 0 for 1.0 seconds
“03” 0 0 0 0 0 0 1 1 for 1.5 seconds
“04” 0 0 0 0 0 1 0 0 for 2.0 seconds
: :
“08” 0 0 0 0 1 0 0 0 for 4.0 seconds
: :
“14” 0 0 0 1 0 1 0 0 for 10.0 seconds
: :
“28” 0 0 1 0 1 0 0 0 for 20.0 seconds
: :
“3C”
0 0
1 1 1 1 0 0 for 30.0 seconds
: :
“78” 0 1 1 1 1 0 0
0 for 60.0 seconds
: :
“B4” 1 0 1 1 0 1 0 0 for 90.0 seconds
: :
“F0” 1 1 1 1 0 0 0 0 for 120.0 seconds
: :
“FF” 1 1 1 1 1 1 1 1 for 127.5 seconds
*4) Snout Control
When using a snout, this function is valid.
n MSW5-F MSW5-E Snout Function
“0”
0 0
Snout Function OFF
“1”
0
1 Snout Function ON (When printing and presenter is operating)
“2” 1 0 Snout Function ON (Error)
“3” 1 1 Snout Function ON (When printing and presenter is operating + Error)